In order to import the geometry, and use this for creating new temporary nodes, select to import “Geometry (nodes and elements)”.
Then in the visibility tree, uncheck “Imported nodes” under Imported “CAD/FE Geometry”, and make “Nodes on Visible Objects” checked.
I see a drastic difference in BEM solve times when recovering Rad Eff. Is this expected?, Yes, computing the BEM radiation efficiency is very expensive as it has to recover the velocity at every wetted node and multiply by the mode shape at that mode, then sum that all up.
For standard BEM one can start with 6-8 elements, and refine from there.
For collocation (used by the FMM solver) the guideline should be 6 to 10 elements.
It is possible to export the modes in erfh5 format of type 1.
You have for that to setup the following environment variable:
PAM_OCTRL_ERFVERSION=1
PSM is much faster than BLOCK_IRAM.
In brief, what’s the difference between using an external vs. internal FE solver in VA One?
The background is that VA One is using structural modes for FE and for FE/SEA hybrid.
These modes can come from two sources:
- Internal VA One Solver
- External solver (NASTRAN, ANSYS, ABAQUS etc.)
To solve for intermediate BEM results, set the solve options to write out files from VA One.
The log window will contain information about where the files are written, MODEL name, and BEM FLUID names,
Why is there a slight difference in subsystem properties for a mirrored ribbed singly curved shell?
The reason is that the normal of the singly curved shell is flipped,