I'm trying to override properties for a fuselage section, but it’s hard to get TL to match - can you give advice?

To view the full version of this page (or to download files), please log in or create a new account

VA One
Vibro-Acoustics
by Emna Ben Ali |8 March 2017
In a pure SEA model, overriding modal density and radiation efficiency (i.e. CLF) normally gives good correlation to a hybrid model.

For the resonant path, if the CLF, MIB and DLF are the same, one would expect the same answer.